EMC 错了么?

原创 eygle 2006-01-10
456

昨天我写到EMC Soft/Hard Read/Write Errors,说EMC建议更换硬盘,可是关于哪一块硬盘产生了分歧.在EMC的Case里,美国专家建议:



Replace drive 0_1_C if not replaced earlier.



因为硬盘编号从0开始C=12,所以我以为应该换的是0_1_13号硬盘,而0_1_13号硬盘也确实是出现错误的一块.可是EMC的现场工程师说0_1_C=0_1_12应该更换0_1_12号硬盘.而0_1_12号一直是没有出现过问题的:









# navicli -h 172.16.9.5 getdisk 0_1_12
Bus 0 Enclosure 1  Disk 12
Vendor Id:               SEAGATE
Product Id:              ST314680 CLAR72
Product Revision:        7A0A
Lun:                     19
Type:                    19: RAID5
State:                   Enabled
Hot Spare:               19: NO
Prct Rebuilt:            19: 100
Prct Bound:              19: 100
Serial Number:           3HY6TKCA
Sectors:                 139681792 (68204)
Capacity:                68238
Private:                 19: 69704
Bind Signature:          0x13cf, 1, 12
Hard Read Errors:        0
Hard Write Errors:       0
Soft Read Errors:        0
Soft Write Errors:       0
Read Retries:     N/A
Write Retries:    N/A
Remapped Sectors:        N/A
Number of Reads:         209288064
Number of Writes:        12913664
Number of Luns:          1
Raid Group ID:           11
Clariion Part Number:    DG118032458 
Request Service Time:    N/A
Read Requests:           209288064
Write Requests:          12913664
Kbytes Read:             1454635954
Kbytes Written:          245519280
Stripe Boundary Crossing: 110585780 