EMC-有多少硬盘可以再坏?

原创 eygle 2007-04-01
525
昨晚,在具体故障尚未定位的情况下,EMC的硬盘坏了2块。



首先是一块RAID 5的硬盘坏了一块,然后一块Hot Spare硬盘顶上。

# navicli -h 172.16.9.5 getdisk 0_0_14

Bus 0 Enclosure 0  Disk 14

Vendor Id:              SEAGATE

Product Id:              ST373307 CLAR72

Product Revision:        7A10

Lun:                    101

Type:                    101: Hot Spare

State:                  Enabled

Hot Spare:              101: YES

Hot Spare Replacing:    0_1_8

Prct Rebuilt:            101: 100

Prct Bound:              101: 100

Serial Number:          3HZ9E674

Sectors:                139681792 (68204)

Capacity:                68238

Private:                101: 69704

Bind Signature:          0x80bd, 0, 14

Hard Read Errors:        0

Hard Write Errors:      0

Soft Read Errors:        6

Soft Write Errors:      6

Read Retries:    N/A

Write Retries:    N/A

Remapped Sectors:        N/A

Number of Reads:        20816685

Number of Writes:        4047067

Number of Luns:          1

Raid Group ID:          101

Clariion Part Number:    DG118032459 

Request Service Time:    N/A

Read Requests:          20816685

Write Requests:          4047067

Kbytes Read:            970975457

Kbytes Written:          105995802

Stripe Boundary Crossing: 0



未几,Hot Spare盘又挂掉了,然后数据开始向原来坏掉的硬盘Equalizing。

这个Equalizing能否正确完成显然是个未知数:

bash-2.03# navicli -h 172.16.9.5 getdisk 0_1_8

Bus 0 Enclosure 1  Disk 8

Vendor Id:              SEAGATE

Product Id:              ST314680 CLAR72

Product Revision:        7A0A

Lun:                    14 15

Type:                    14: RAID5 15: RAID5

State:                  Equalizing

Hot Spare:              14: NO 15: NO

Prct Rebuilt:            14: 100 15: 100

Prct Bound:              14: 100 15: 100

Serial Number:          3HY6RV4L

Sectors:                104857600 (51200)

Capacity:                68238

Private:                14: 69704 15: 104927304

Bind Signature:          0xc3de, 1, 8

Hard Read Errors:        0

Hard Write Errors:      0

Soft Read Errors:        0

Soft Write Errors:      0

Read Retries:    N/A

Write Retries:    N/A

Remapped Sectors:        N/A

Number of Reads:        3922772

Number of Writes:        6092245

Number of Luns:          2

Raid Group ID:          9

Clariion Part Number:    DG118032458 

Request Service Time:    N/A

Read Requests:          3922772

Write Requests:          6092245

Kbytes Read:            472965617

Kbytes Written:          403726059

Stripe Boundary Crossing: 392467



马上Call EMC,喊人连夜换掉了两块硬盘。



坏掉的硬盘和并不属于前几日故障LUN,但是同在一个Storage Group之中,与先前的故障应该没有直接的关联。

目前发现一台主机的PowerPath存在问题,这个问题导致一路光纤通道出现问题,这个故障导致部分LUN的Trespass。



-The End-
「喜欢这篇文章,您的关注和赞赏是给作者最好的鼓励」
关注作者
【版权声明】本文为墨天轮用户原创内容,转载时必须标注文章的来源(墨天轮),文章链接,文章作者等基本信息,否则作者和墨天轮有权追究责任。如果您发现墨天轮中有涉嫌抄袭或者侵权的内容,欢迎发送邮件至:contact@modb.pro进行举报,并提供相关证据,一经查实,墨天轮将立刻删除相关内容。

评论