F5 BIG-IP 6900 硬盘更换说明

IT那活儿 2022-10-17
1277

点击上方“IT那活儿”公众号,关注后了解更多内容,不管IT什么活儿,干就完了!!!




本更换方案适用于BIG-IP 6900软件版本10.1.X 以上版本。




识别故障硬盘

1. 检查RAID状态信息(failed 硬盘故障)
tmsh show sys raid
显示磁盘摘要:
Sys::Raid::Array: MD1
---------------------
Size (MB) XXXXXX

Sys::Raid::ArrayMembers
Bay ID Serial Number Name Array Member Array Status
---------------------------------------------------------
1       WD- XXXXXXXXXXXX HD2 yes failed
2       WD- XXXXXXXXXXXX HD1 yes ok

Sys::Raid::Bay: 1
---------------------------------------------------------
Name Serial Number Array Member Array Status
HD2 WD- XXXXXXXXXXXX yes failed

Sys::Raid::Bay: 2
---------------------------------------------------------
Name Serial Number Array Member Array Status
HD1 WD- XXXXXXXXXXXX yes ok

Sys::Raid::Disk
Name Serial Number Array Member Array Status
------------------------------------------------------
HD1 WD-XXXXXXXXXXXX yes ok
HD2 WD- XXXXXXXXXXXX yes failed

2. 记下故障硬盘槽位号和序列号
3. 卸载硬盘阵列(在物理卸下硬盘之前,尽量从阵列中删除故障硬盘)
Tmsh modify sys raid array MD1 remove HD2
Tmsh modify sys raid array MD1 remove HD2

4. 更换硬盘(支持热插拔,不必关闭电源)

  1. 卸下前挡板
  2. 通过比对序列号及槽位号验证故障硬盘物理位置
  3. 卸下故障硬盘
  4. 插入新硬盘
5. 验 证
使用tmsh show sys raid查询状态
Sys::Raid::Array: MD1
---------------------
Size (MB) XXXXXX

Sys::Raid::ArrayMembers
Bay ID Serial Number Name Array Member Array Status
---------------------------------------------------------
1       WD- XXXXXXXXXXXX HD2 yes undefined
2       WD- XXXXXXXXXXXX HD1 yes ok

6. 将新硬盘加入阵列
tmsh modify sys raid array MD1 add HD2

完成!