点击上方“IT那活儿”公众号,关注后了解更多内容,不管IT什么活儿,干就完了!!!
本更换方案适用于BIG-IP 6900软件版本10.1.X 以上版本。
识别故障硬盘
tmsh show sys raid
Sys::Raid::Array: MD1
---------------------
Size (MB) XXXXXX
Sys::Raid::ArrayMembers
Bay ID Serial Number Name Array Member Array Status
---------------------------------------------------------
1 WD- XXXXXXXXXXXX HD2 yes failed
2 WD- XXXXXXXXXXXX HD1 yes ok
Sys::Raid::Bay: 1
---------------------------------------------------------
Name Serial Number Array Member Array Status
HD2 WD- XXXXXXXXXXXX yes failed
Sys::Raid::Bay: 2
---------------------------------------------------------
Name Serial Number Array Member Array Status
HD1 WD- XXXXXXXXXXXX yes ok
Sys::Raid::Disk
Name Serial Number Array Member Array Status
------------------------------------------------------
HD1 WD-XXXXXXXXXXXX yes ok
HD2 WD- XXXXXXXXXXXX yes failed

Tmsh modify sys raid array MD1 remove HD2
4. 更换硬盘(支持热插拔,不必关闭电源)
卸下前挡板 通过比对序列号及槽位号验证故障硬盘物理位置 卸下故障硬盘 插入新硬盘
Sys::Raid::Array: MD1
---------------------
Size (MB) XXXXXX
Sys::Raid::ArrayMembers
Bay ID Serial Number Name Array Member Array Status
---------------------------------------------------------
1 WD- XXXXXXXXXXXX HD2 yes undefined
2 WD- XXXXXXXXXXXX HD1 yes ok
tmsh modify sys raid array MD1 add HD2
完成!

本文作者:闫 浩(上海新炬王翦团队)
本文来源:“IT那活儿”公众号