Exadata db节点网卡异常down处理

IT那活儿 2022-12-06
3313
点击上方“IT那活儿”公众号,关注后了解更多内容,不管IT什么活儿,干就完了!!!

背景

日常巡检发现db节点ib1网卡异常down了,查看链路状态也是down,通过ifconfig ib1 down/up也无法恢复。
  • 环境
    exadata x8-2
    Image version: 21.2.6
1.1 ib1网卡状态没有running
ib0: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 65520
inet 192.168.XX.35 netmask 255.255.252.0 broadcast 192.168.XX.255
inet6 fe80::ba59:9f03:91:7fd1 prefixlen 64 scopeid 0x20<link>
Infiniband hardware address can be incorrect! Please read BUGS section in ifconfig(8).

infiniband 80:00:02:08:FE:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00 txqueuelen 256 (InfiniBand)
RX packets 441801234 bytes 135108307679 (125.8 GiB)
RX errors 0 dropped 0 overruns 0 frame 0
TX packets 571055390 bytes 386080892808 (359.5 GiB)
TX errors 0 dropped 200 overruns 0 carrier 0 collisions 0

ib1: flags=4099<UP,BROADCAST,MULTICAST> mtu 65520
Infiniband hardware address can be incorrect! Please read BUGS section in ifconfig(8).
infiniband 80:00:02:09:FE:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00 txqueuelen 256 (InfiniBand)

RX packets 44482253 bytes 15202598429 (14.1 GiB)
RX errors 0 dropped 0 overruns 0 frame 0
TX packets 16442693 bytes 4497934510 (4.1 GiB)
TX errors 0 dropped 16 overruns 0 carrier 0 collisions 0

ib0:P02: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 65520
inet 192.168.XX.36 netmask 255.255.252.0 broadcast 192.168.XX.255
Infiniband hardware address can be incorrect! Please read BUGS section in ifconfig(8).
infiniband 80:00:02:08:FE:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00 txqueuelen 256 (InfiniBand)

lo: flags=73<UP,LOOPBACK,RUNNING> mtu 65536
inet 127.0.0.1 netmask 255.0.0.0
inet6 ::1 prefixlen 128 scopeid 0x10<host>
loop txqueuelen 1000 (Local Loopback)
RX packets 64915590345 bytes 15540910225759 (14.1 TiB)
RX errors 0 dropped 0 overruns 0 frame 0
TX packets 64915590345 bytes 15540910225759 (14.1 TiB)
TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0

1.2 链路显示down了
Infiniband device 'mlx4_0' port 1 status:
default gid: fe80:0000:0000:0000:b859:9f03:0091:7fd1
base lid: 0x2b
sm lid: 0x13
state: 4: ACTIVE
phys state: 5: LinkUp
rate: 40 Gb/sec (4X QDR)
link_layer: InfiniBand

Infiniband device 'mlx4_0' port 2 status:
default gid: fe80:0000:0000:0000:b859:9f03:0091:7fd2
base lid: 0x2c
sm lid: 0x13
state: 1: DOWN
phys state: 2: Polling
rate: 10 Gb/sec (4X)
link_layer: InfiniBand

1.3 db节点alert日志显示IB交换机端口异常
359_1 2022-02-05T22:28:34+08:00 critical "InfiniBand port 
HCA-1:2 is in an invalid state. State : Down Physical Link 
State : Polling Data Rate : 10 Gps Symbol Errors : 0 Received Errors : 0"

到这里可以排除网卡损坏,开始核查所有ib交换机状态。


分析原因

在所有ib交换机上执行检查,发现iba01存在异常。
Environment test started:
Starting Environment Daemon test:
Environment daemon running
Environment Daemon test returned OK
Starting Voltage test:
Voltage ECB OK
Measured 3.3V Main = 3.25 V
Measured 3.3V Standby = 3.37 V
Measured 12V = 11.97 V
Measured 5V = 4.99 V
Measured VBAT = 3.03 V
Measured 2.5V = 2.48 V
Measured 1.8V = 1.78 V
Measured I4 1.2V = 1.21 V
Voltage test returned OK
Starting PSU test:
PSU 0 present OK
PSU 1 present OK
PSU test returned OK
Starting Temperature test:
Back temperature 29
Front temperature 31
SP temperature 46
Switch temperature 57, maxtemperature 60
Temperature test returned OK
Starting FAN test:
Fan 0 not present
Fan 1 running at rpm 15478
Fan 2 running at rpm 15696
Fan 3 running at rpm 15696
Fan 4 not present
FAN test returned OK
Starting Connector test:
Connector test returned OK
Starting Onboard ibdevice test:
Switch OK
All Internal ibdevices OK
Onboard ibdevice test returned OK
Starting SSD test:
SSD test returned OK
Starting Auto-link-disable test:
WARNING Autodisabled ports
Auto-link-disable test returned 1 faults
Environment test FAILED

# listlinkup
Connector 0A Present <-> Switch Port 20 is up (Enabled)
Connector 1A Present <-> Switch Port 22 is down (AutomaticHighErrorRate)
Connector 2A Present <-> Switch Port 24 is down (Enabled)
Connector 3A Present <-> Switch Port 26 is up (Enabled)
Connector 4A Present <-> Switch Port 28 is up (Enabled)
Connector 5A Present <-> Switch Port 30 is up (Enabled)

# showunhealthy
WARNING Autodisabled ports
FAILURE - 1 sensors NOT OK

vendid=0x2c9
devid=0x1003
sysimgguid=0xb8599f0300917fd3
caguid=0xb8599f0300917fd0
Ca 2 "H-b8599f0300917fd0" # "exdadbadm10 S 192.168.XX.35,192.168.XX.36 HCA-1"
[1](b8599f0300917fd1) "S-0010e0cdd353a0a0"[22] # lid 43 lmc 0 "SUN DCS 36P QDR exdasw-ibb01 168.168.XX.37" lid 26 4xQDR

可以确认,连接ib1的连接端口22有报错,而22端口由于high error rate导致处于关闭状态。


处理步骤

3.1 首先清理报错信息
[root@exdasw-iba01 ~]# ibclearerrors

## Summary: 35 nodes cleared 0 errors
[root@exdasw-iba01 ~]#
[root@exdasw-iba01 ~]#
[root@exdasw-iba01 ~]# ibclearcounters

## Summary: 35 nodes cleared 0 errors

3.2 启用IB交换机端口并验证
[root@exdasw-iba01 ~]# enableswitchport --automatic 22

[root@exdasw-iba01 ~]# listlinkup
Connector 0A Present <-> Switch Port 20 is up (Enabled)
Connector 1A Present <-> Switch Port 22 is up (Enabled)

Starting Onboard ibdevice test:
Switch OK
All Internal ibdevices OK
Onboard ibdevice test returned OK
Starting SSD test:
SSD test returned OK
Starting Auto-link-disable test:
Auto-link-disable test returned OK

可以看到状态已经恢复正常。
再次检查db节点ib01网卡,无需人工处理,该网卡已经处于running状态。
3.3 开始清理告警日志
[root@exdasw-iba01 ~]# spsh

Oracle(R) Integrated Lights Out Manager

Version 2.2.16-3 ILOM 3.2.11 r137127

Copyright (c) 2020, Oracle and/or its affiliates. All rights reserved.

Warning: HTTPS certificate is set to factory default.

Hostname: exdasw-iba01

-> show faulty
Target | Property | Value
----------------------------------+----------------------------------------+-----------------------------------------------------------
/SP/faultmgmt/0                   | fru | SYS
/SP/faultmgmt/0/faults/0          | class | fault.device.ib.auto-link-disable
/SP/faultmgmt/0/faults/0          | sunw-msg-id | ---
/SP/faultmgmt/0/faults/0          | component | /SYS
/SP/faultmgmt/0/faults/0          | uuid | 8f0fd5cf-661b-e0f5-db37-cfbcbd7b673a
/SP/faultmgmt/0/faults/0          | timestamp | 2022-02-02/10:18:11


-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2022-02-05/22:22:57 57471550-2815-eba0-ef6b-f46fa7788bad IBSWITCH-8000-D6 Major

Fault class : fault.chassis.device.ib.link-error

FRU : /SYS
(Part Number: 7305544)
(Serial Number: AK00417399)

Description : One or more ports have been auto-disabled due to high error
rate or bad link speed or width.

Response : Illuminate service-required LED on the chassis.

Impact : One or more ports have been auto-disabled due to high error
rate or bad link speed or width.

Action : Please refer to the associated reference document at %s for
the latest service procedures and policies regarding this
diagnosis.

faultmgmtsp> fmadm repair 57471550-2815-eba0-ef6b-f46fa7788bad
faultmgmtsp> fmadm faulty
No problems found
faultmgmtsp> show faulty
Invalid command 'show' - type help for a list of commands.

faultmgmtsp> exit
-> show faulty
Target | Property | Value
------------------------------------------------+--------------------------------------------------------+---------------------------------------------------------------------------------

->

总 结
当网卡出现异常时,不一定是硬件损坏,需要核查整个链路上的组件运行状态。


本文作者汤 杰(上海新炬中北团队)

本文来源:“IT那活儿”公众号

文章转载自IT那活儿,如果涉嫌侵权,请发送邮件至:contact@modb.pro进行举报,并提供相关证据,一经查实,墨天轮将立刻删除相关内容。