CRS-07506:Failed to establish bootstap connetion with node 'string'

错误码

错误描述:Failed to establish bootstap connetion with node 'string'
错误原因:The reason this issue was one of the following:- All the private interconnects were down either on the local node or on the remote node.- The bootstrap process on the remote node was not running.- The process on the remote node was hung.- The network had issues.- There were multicast issues either on the local node or on the remote node.
解决方法:(a) Check the status of the private interconnects on both nodes. (b) Check if the process on the remote node is running. (c) Check if the Oracle Grid Interprocess Communication (GIPC) high availability threads of the remote process are running. (d) Execute the cluvfy binary and check the transmission control protocol/user datagram protocol (TCP/UDP) connectivity between the local node and the remote node. (e) Execute the cluvfy binary on the local node and check the multicast functionality between the local node and the remote node.